set radius enable
set radius server 1 10.0.xx.y7 1812 supersecret realm any
set radius server 2 10.0.xx.y8 1812 supersecret realm any
on the acs
Radius reply item must be
Filter-ID = Enterasys:version=1:mgmt=su
set radius enable
set radius server 1 10.0.xx.y7 1812 supersecret realm any
set radius server 2 10.0.xx.y8 1812 supersecret realm any
on the acs
Radius reply item must be
Filter-ID = Enterasys:version=1:mgmt=su
set tacacs enable
set tacacs command authorization enable
set tacacs singleconnect enable
set tacacs server 1 10.0.xx.y9 49 supersecret
set tacacs server 2 10.0.xx.y8 49 supersecret
[sourcecode]
set snmp access gReadOnlyV1V2C security-model v1 exact read vUnsecured
set snmp access gReadOnlyV1V2C security-model v2c exact read vUnsecured
set snmp community mycomunity securityname sn_v1v2c_ro
set snmp group gReadOnlyV1V2C user sn_v1v2c_ro security-model v1
set snmp group gReadWriteV1V2C user sn_v1v2c_rw security-model v1
set snmp group gReadOnlyV1V2C user sn_v1v2c_ro security-model v2c
set snmp group gReadWriteV1V2C user sn_v1v2c_rw security-model v2c
set snmp view viewname vUnsecured subtree 1
set snmp view viewname vUnsecured subtree 0.0
[/sourcecode]
If you feel this helps a bit or may be not ? Please leave a comment.
To enable the SSH Service on a Enterasys SecureStack C2 and similar you have to issue “set ssh enabled” on the cli.
[sourcecode autolinks=”false” gutter=”false” highlight=”2″]
C2(su)->set ssh enabled
SSH hostkey generation initiated. Process should complete in 60 seconds.
C2(su)->
[/sourcecode]
If you feel this helps a bit or may be not ? Please leave a comment.
Configuring Traffic Shaping on the Enterasys C2 Switch.